TVE-Q_img_01psd.png
VAV terminal unit variant TVE-Q (standard, galvanised steel)
TVE-Q_img_08psd.png
Differential pressure measurement via damper blade

Differential pressure measurement via damper blade

TVE-Q_img_09psd.png
Compact controller with display

Compact controller with display

TVE_gc_09V2ai.png
Installation directly on the main duct

Installation directly on the main duct

doc_graphic_000009.png
Tested to VDI 6022

Conforms to VDI 6022

TVE-Q_img_01psd.png
TVE-Q_img_08psd.png
TVE-Q_img_09psd.png
TVE_gc_09V2ai.png
doc_graphic_000009.png

TVE-Q 

Compact solution for low airflow velocities

Angular air terminal units for use in variable air terminal systems at low air velocities, even under unfavourable upstream conditions


  • Tubeless differential pressure measurement via damper blade
  • Differential pressure transmission through differential pressure duct in axis
  • Connection terminals with protective cover, no junction box required
  • Any airflow direction if dynamic transducer is used
  • Suitable for air velocities from 0.8 - 8 m/s
  • Compact dimensions for use in confined ceiling areas
  • Plug-and-play solution in conjunction with X-AIRCONTROL room control
  • Exact measurement even with low airflow velocities
  • Any installation orientation also with static transducer
  • Closed blade air leakage to EN 1751, at least class 3
  • Casing air leakage to EN 1751, class C
  • Volume flow rate range 1:10

 


Optional equipment and accessories


  • Secondary silencer to reduce air-regenerated noise
  • Hot water heat exchanger Type WT for reheating the airflow

General information



Application

  • Square VAV terminal units for use in ventilation and air conditioning systems (AHUs)
  • For almost all tasks when controlling, restricting, or shutting off supply and extract air flows
  • Also for unfavourable upstream conditions at low air velocities
  • Closed-loop volume flow control using an external power supply
  • For variable or constant volume flow systems
  • Shut-off by override control (by the client)


Special characteristics

  • High differential pressure signal with small angle of attack
  • Factory set-up or programming and aerodynamic function testing
  • Volume flow rate can be measured and subsequently adjusted. Additional adjustment tool may be required (depending on the variant of the control component)
  • Tubeless differential pressure measurement via damper blade
  • Differential pressure transmission through differential pressure duct in axis
  • Any airflow direction if dynamic transducer is used
  • Any installation orientation also with static transducer
  • Suitable for air velocities from 0.8 - 8 m/s
  • Compact dimensions for use in confined ceiling areas


Nominal sizes

  • 200 × 100, 300 × 100
  • 200 × 200, 300 × 200, 400 × 200, 500 × 200, 600 × 200


Variants

  • TVE-Q: VAV terminal unit
  • TVE-Q with TX secondary silencer to reduce air-regenerated noise

Construction

  • Galvanised sheet steel
  • P1: Powder-coated, silver grey (RAL 7001)


Parts and characteristics

  • Ready-to-commission unit which consists of mechanical parts and control components.
  • Damper blade with integrated measuring unit
  • Axis with differential pressure duct for measured value transmission
  • Control component factory mounted
  • Each unit is tested on a special aerodynamic test rig at the factory
  • Documentation of the test rig data with a test label or a volume flow scale on the unit
  • High control accuracy even in case of unfavourable upstream conditions


Attachments

  • EASY controller: compact unit consisting of controller with potentiometers, differential pressure transducer and actuator
  • Compact controller: compact unit consisting of controller, differential pressure transducer and actuator
  • Compact controller Modbus: variant with Modbus RTU interface and disply; Plug-and-play solution in conjunction with X-AIRCONTROL room control
  • Compact controller BACnet: Variant with BACnet-MS/TP interface and display; can also be converted to Modbus RTU by the customer



Useful additions

  • Secondary silencer Type TX for the reduction of airregenerated noise
  • Hot water heat exchanger Type WT for reheating the airflow


Construction features

  • Rectangular casing
  • Flanges on both ends, suitable for duct connections
  • Position of the damper blade indicated externally at position indicator
  • Simple exchange of the control components possible


Material and surfaces

Galvanised sheet steel
  • Casing, damper blade made of galvanised sheet steel
  • Shaft made of PA6 (H ≤ 200) or aluminium (H > 200)
  • Damper blade seal and sealing plug made of EPDM
  • Bearing bushes made of PBT or TPU
  • Fastening (screws, rivets) Galvanised steel, aluminium
Powder-coated construction (P1)
  • Casing, damper blade galvanised with powder coating, RAL 7001, silver-grey
  • Shaft made of PA6 (H ≤ 200) or aluminium (H > 200)
  • Damper blade seal and sealing plug made of EPDM
  • Bearing bushes made of PBT or TPU
  • Fastening (screws, rivets) stainless steel, aluminium


Standards and guidelines

Meets the hygiene requirements of
  • EN 16798, Part 3
  • VDI 6022, Sheet 1
  • DIN 1946, Part 4
  • For further standards and guidelines, please refer to the hygiene certificate
Casing air leakage
  • EN 1751, Class C
Closed damper blade air leakage:
NS 200 × 100, NS 300 × 100, NS 200 × 200
  • EN 1751, Class 2
NS 300 × 200, NS 400 × 200, NS 500 × 200, NS 600 × 200
  • EN 1751, Class 3


Maintenance

  • Maintenance-free as construction and materials are not subject to wear and tear

Tehnički podaci

Function, Technical data, Specification text, Order Code

  • Function
  • TECHNICAL DATA
  • QUICK SIZING
  • SPECIFICATION TEXT
  • ORDER CODE
TVE-Q_gc_09ai.png

1 Flange for air duct profiles
2 Casing
3 Damper blade including differential pressure sensor
4 Axis with differential pressure duct
5 Electronic volume flow controller
6 Preferred airflow direction

Functional description

The damper blade works as a control element and as a differential pressure sensor. Through the differential pressure duct in the shaft, the detected differential pressure reaches the transducer (static or dynamic), and is converted into an electrical signal and compared with the setpoint value. In case of a control deviation, the integrated actuator changes the position of the damper blade. Thereby, the volume flow rate is kept constant in close tolerances over the entire differential pressure range.

Nominal sizes
  • 200 × 100, 300 × 100
  • 200 × 200, 300 × 200, 400 × 200, 500 × 200, 600 × 200
Volume flow rate range

16 - 960 l/s or 58 - 3456 m³/h

Volume flow rate control range (controller with dynamic differential pressure measurements)

approx. 10 - 100 % of the nominal volume flow rate

Minimum differential pressure

up to 50 Pa (without secondary silencer)

Maximum differential pressureControl component with dynamic transducer: 900 Pa, Control component with static transducer: 600 Pa
Operating temperature10 to 50 °C

 


 

Quick sizing tables provide a good overview of the minimum pressure differences, the volume flow accuracy Δqv and the expected sound pressure levels in the room. Intermediate values may be achieved by interpolation. The sound power levels for calculating the sound pressure levels were measured in the TROX laboratory according to DIN EN ISO 5135 - see "Basic information and nomenclature". Precise results and spectral data for all control components can be obtained by using our Easy Product Finder design programme. The nominal size is initially selected according to the given volume flow rates qvmin and qvmax.

Volume flow rate ranges and minimum differential pressure values
The minimum differential pressure of VAV terminal units is an important factor in designing the ductwork and in rating the fan including speed control. It must be ensured that for all operating conditions and for all terminal units, a sufficient differential pressure is applied to each controller (Δpstmin). The measurement point(s) for fan speed control must be selected accordingly. The volume flow rate range for VAV terminal units depends on the nominal size and on the control component (attachment) used.

Volume flow rate ranges and minimum differential pressure values
Controller for dynamic and static pressure measurements
Attachment: Easy, XB0, XM0, XM0-J6, XS0, XS0-J6

BH

qv [l/s]

qv [m³/h]

Δpstmin [Pa]

Δqv [±%]

(1)(2)
20010016581318
200100642308338
200100112403251016
200100160576502045
30010025871318
300100963468338
300100168605241006
300100240864482025
200200331161218
2002001284616228
20020022480618666
2002003201152371335
300200481731218
3002001926916228
300200336121017656
3002004801728351315
400200652311218
4002002569226228
400200448161317656
4002006402304341305
500200802881218
50020032011526228
500200560201616646
5002008002880331295
600200963461218
60020038413826228
600200672241916646
6002009603456331295

(1) Basic unit
(2) Basic unit with secondary silencer TX


Quick sizing table for sound pressure levels
The quick sizing tables include common sound insulation and attenuation values. If the sound pressure level is above the permissible value, a larger air terminal unit and/or a silencer or acoustic cladding are required. For more information on the acoustic data, see Basic Information and Nomenclature.


Quick sizing table for air-regenerated noise LPA
Controller including silencer variants

BH

qv [l/s]

qv [m³/h]

150 Pa500 Pa
(1)(2)(1)(2)
20010016583115

40

22
2001006423040254932
20010011240344295236
20010016057648

n. V.

5439
300100258725103618
3001009634637234832
30010016860542305236
30010024086446

n. V.

5439
2002003311632194227
20020012846142295237
20020022480644305339
200200320115245305440
3002004817335194730
30020019269144275538
300200336121045285739
300200480172846305839
4002006523131174327
40020025692238245035
400200448161339265137
400200640230440295238
5002008028833154426
500200320115240245134
500200560201642265336
500200800288043295438
6002009634632174427
600200384138238245034
600200672241940255136
600200960345641295237

(1) Basic unit
(2) Basic unit with secondary silencer TX

n.a.: Specified static differencial pressure Δpst is smaller than minimum differential pressure Δpstmin.


Quick sizing table for case-radiated noise LPA

BH

qv [l/s]

qv [m³/h]

150 Pa500 Pa
(1)
20010016581826
200100642302735
2001001124033039
2001001605763541
30010024871324
300100963462636
3001001686053141
3001002408643745
200200321162029
2002001284613039
2002002248063443
20020032011523646
300200481732436
3002001926913446
30020033612103850
30020048017284052
400200642311931
4002002569222941
40020044816133345
40020064023043547
500200802882031
50020032011523142
50020056020163546
50020080028803849
600200963461931
60020038413822941
60020067224193345
60020096034563648

(1) Basic unit


Specification text

VAV terminal units in rectangular design for variable and constant volume flow systems, for supply air or extract air, in several nominal sizes. High control accuracy of set volume flow rates, even in unfavourable upstream conditions. Control range at least 1:10. Differential pressure measurement and control via damper blade. Tubeless differential pressure transmission through differential pressure duct in shaft Closed blade air leakage according to EN 1751: class 2 or 3 depending on nominal size. Casing air leakage according to EN 1751, class C Ready-to-commission unit which consists of the mechanical parts and the factory mounted electronic control component. Position of the damper blade indicated externally at the control component. The damper blade is factory set to open position, which allows a ventilation airflow even without control. Meets the hygiene requirements of EN 16798, Part 3, of VDI 6022, Sheet 1, and of DIN 1946, Part 4.


Special characteristics

  • High differential pressure signal with small angle of attack
  • Factory set-up or programming and aerodynamic function testing
  • Volume flow rate can be measured and subsequently adjusted. Additional adjustment tool may be required (depending on the variant of the control component)
  • Tubeless differential pressure measurement via damper blade
  • Differential pressure transmission through differential pressure duct in axis
  • Any airflow direction if dynamic transducer is used
  • Any installation orientation also with static transducer
  • Suitable for air velocities from 0.8 - 8 m/s
  • Compact dimensions for use in confined ceiling areas


Materials and surfaces

  • Casing and damper blade made of galvanised sheet steel
  • Shaft made of PA6, UL94-V0 (H ≤ 200) or aluminium (H > 200)
  • Closed-cell damper blade seal made of EPDM
  • Bearings made of plastic


Equivalence criteria

  • Declaration of hygiene conformity in accordance with VDI 6022, part 1 (01/2018), ÖNORM H 6020 (03/2015) and ÖNORM H 6021 (08/2016)
  • Independent of air direction - air flow in both directions
  • Suitable for airflow velocities of 0.8 – 8 m/s
  • No inflow lengths required (even after T-piece)
  • Meets the hygiene requirements according to EN 16798 Part 3, VDI 6022 Sheet 1, DIN 1946 Part 4
  • Setting the volume flow rates without adjustment device via Vmin- and Vmax-potentiometer
  • Electrical connections with screw terminals, no additional connection box required
  • Acoustic data determined according to ÖNORM EN ISO 5135
  • Maximum control deviation of 5 % at qvmax, without upstream section


Connection type

  • Flanges on both ends, suitable for duct connections


Technical data

  • Minimum differential pressure: up to 50 Pa (without secondary silencer)
Maximum differential pressure
  • Control component with dynamic transducer: 900 Pa
  • Control component with static transducer: 600 Pa
Closed blade air leakage, class 2 or 3 depending on nominal size.


Specification text attachment

Variable volume flow control with electronic Easy controller for applying a reference value and capturing an actual value to be integrated with the central BMS.
  • 24 V AC/DC supply voltage
  • Signal voltages 0 – 10 V DC
  • Possible override controls with external switches using voltfree contacts: CLOSE, OPEN, qvmin and qvmax
  • Potentiometers with percentage scales to set the volume flow rates qvmin and qvmax
  • The actual value signal relates to the nominal volume flow rate so that commissioning and subsequent adjustment are simplified
  • Volume flow rate control range: approx. 10 – 100% of the nominal volume flow rate
  • Visible indicator light for signalling the various operating conditions
  • Electrical connections with screw terminals.
  • Double screw terminals for looping the supply voltage, i.e. for simple connection of voltage transmission to the next controller.


Life cycle assessment

A life cycle assessment is available for the product series in form of an Environmental Product Declaration (EPD) that has been checked and published by a programme holder.

Order code for volume flow control (with Easy controller)


TVE-Q/300 × 200/Easy
|||
135
1 Type
TVE-Q VAV air terminal unit

3 Nominal size [mm]
Specify width × height

5 Attachments (control component)
Easy Volume flow controller, dynamic, analogue interface, setting of qvmin and qvmax with potentiometers provided by others


Order example: TVE-Q/300×200/Easy

TypeTVE-Q
Nominal size [mm]Width 300, height 200
Attachments (control component)Volume flow controller, dynamic, analogue interface, setting of qvmin and qvmax with potentiometers provided by others


,Order code for volume flow control (with VARYCONTROL attachment)


TVE-QP1/300 × 200/XB0/V0/200 – 900 [m³/h]
|||||||
1345678
1 Type
TVE-Q
VAV air terminal unit

3 Material
No entry: galvanised sheet steel
P1 Air duct powder-coated RAL 7001, silver grey

4 Nominal size [mm]
Specify width × height

5 Attachment (control component)
XB0
Dynamic volume flow controller, analogue interface
XM0 Dynamic volume flow controller with display, interface Modbus RTU or analogue
XM0-J6 Dynamic volume flow controller with display, Modbus RTU interface, RJ12 socket (for X-AIRCONTROL)
XS0 Static volume flow controller with display, Modbus RTU or analogue interface
XS0-J6 Static volume flow controller with display, Modbus RTU interface, RJ12 socket (for X-AIRCONTROL)
XDMB0 Dynamic volume flow controller with display, Modbus RTU or BACnet MS/TP or analogue interface
XSMB0 Static volume flow controller with display, Modbus RTU or BACnet MS/TP or analogue interface

6 Operating mode
For attachments XB0, XM0, XS0
F Constant value mode, one setpoint value (no external switch contact)
V Variable operation (default setpoint value from analogue signal)

For attachments XM0, XM0-J6, XS0, XS0-J6
M Modbus RTU interface, variable operation (default setpoint value in Modbus register)

For attachments XDMB0, XSMB0
B BACnet MS/TP interface, variable operation (setpoint specification via BACnetObject)

7 Signal voltage range
Only with operating mode F or V
0 0 – 10 V DC
2 2 – 10 V DC

8 Operating values for factory setting
Volume flow rate [m³/h or l/s]
qvconst (with operating mode F)
qvmin – qvmax (for operating mode V, M, B)


Order example: TVE-Q-P1/500×200/XB0/V0/850-2200[m³/h]

TypeTVE-Q
MaterialAir duct powder-coated RAL 7001, silver grey
Nominal size [mm]Width 500, height 200
Attachments (control component)Volume flow controller, dynamic, analogue interface
Operating modeVariable operation
Signal voltage range0 – 10 V DC
Operating values for factory setting850 – 2200 [m³/h]

Variants, Product Details

  • VARIANTS
  • PRODUCT DETAILS


Installation and commissioning

  • Almost any installation orientation
  • EN 1505 must be considered when making air duct connections, such as the junction from a main duct


Upstream conditions

The differential pressure, which is decisive for the volume flow rate, is recorded and averaged on the damper blade. Therefore, the volume flow rate accuracy Δqv is independent of the upstream length, but in case of junctions from the main line, dependent on the installation variant of the control unit in the branch duct.


TVE-Q control components VARYCONTROL

AttachmentControlled variableInterfaceEffective pressure transducerActuatorManufacturer
Easy controller, dynamic
Easy

qv

0 – 10 VintegratedSlow running

integrated

(1)

Compact controller, dynamic
XB0

qv

0 – 10 V or 2 – 10 VintegratedSlow running

integrated

(1)

XM0

qv



Modbus RTU interface


integratedSlow running

integrated

(1)

XM0–J6

qv



Modbus RTU interface with RJ12 socket (for X-AIRCONTROL)


integratedSlow running

integrated

(1)

Compact controller, static
XS0

qv



Modbus RTU interface


integratedSlow running

integrated

(1)

XS0–J6

qv

Modbus RTU interface with RJ12 socket (for X-AIRCONTROL)

integratedSlow running

integrated

(1)

qv Volume flow rate
(1) TROX

Preuzimanja

informacije o proizvodima

certifikati

production {"X-Frame-Options"=>"SAMEORIGIN", "X-XSS-Protection"=>"1; mode=block", "X-Content-Type-Options"=>"nosniff", "X-Download-Options"=>"noopen", "X-Permitted-Cross-Domain-Policies"=>"none", "Referrer-Policy"=>"strict-origin-when-cross-origin", "Content-Security-Policy"=>"frame-ancestors 'self' https://api.scrivito.com https://punchoutcommerce.com https://www.trox.de https://trox-extern.com https://psp40.onventis.com https://psp22.onventis.com https://trox4u.troxgroup.com", "Strict-Transport-Security"=>"max-age=31536000; includeSubDomains", "Content-Type"=>"text/html; charset=utf-8"}

Kontakt

Tu smo za vas

Preporučite ovu stranicu slanjem poveznice poštom.

Polja označena s (*) su obvezna polja

Podijeli stranicu

Zahvaljujemo na preporuci!

Vaša je preporuka poslana i trebala bi stići uskoro.

Kontakt

Tu smo za vas

Navedite svoju poruku i vrstu zahtjeva
Tel.: +385 1 61 55 401 | +385 1 61 58 598

Polja označena s (*) su obvezna polja.

Kontakt

Zahvaljujemo na vašoj poruci!

Vaša je poruka poslana i ubrzo će biti obrađena.
Naš odjel za servisne zahtjeve što skorije će vas kontaktirati.
Za opća pitanja u vezi s proizvodima ili uslugama možete i nazvati:
Tel.: +385 1 61 55 401 | Faks: +385 1 61 58 598

Kontakt

Tu smo za vas

Navedite svoju poruku i vrstu zahtjeva
Tel.: +385 1 61 55 401 | +385 1 61 58 598

Attachment (max. 10MB)

Polja označena s (*) su obvezna polja.

Kontakt

Zahvaljujemo na vašoj poruci!

Vaša je poruka poslana i ubrzo će biti obrađena.
Naš odjel za servisne zahtjeve što skorije će vas kontaktirati.
Za opća pitanja u vezi s proizvodima ili uslugama možete i nazvati:
Tel.: +385 1 61 55 401 | Faks: +385 1 61 58 598